Advanced wood processing technology using microwave!
1. Product name | ||
PACEP wood sterilizing and drying device (model name: MAMA-6H) | ||
2. Specifications | ||
① Output | 14 2.45GHz Microwave 3kw modules = 42kw total | |
Module specification | Up to 1.2 kw/hr class Magnetron 3ea 3 Switched-Mode Power Supply / 7 cooling fans 55w/hr |
|
1 module power consumption | 3.7 kw/hr max | |
② Power consumption | Up to 72KVA or less (including control and fan power) | |
③ Size specification | Maximum size of treated wood | Width 500 Height 900 Length 5,600 (mm) |
Internal standard of processing chamber | Width 1,000 Height 1,000 Length 6,500 (mm) | |
External standard of processing device | Width 1,500 Height 1,300 Length 14,000 (mm) (External connecting rail 6,500 mm) | |
④ Input power | 380V 3-phase, 4-wire (power 3-wire, neutral) | |
grounding | 3 kinds of grounding or more | |
⑤ Control panel | Main block switch | 200A (recommended) |
Microwave output on/off general control, time control (operation and pause time) | ||
Microwave output on/off for each module | ||
⑥ External air supply fan | units of 25watt class | |
⑦ Material | inner side plate; steel, structure bar & others; steel | |
3. Operation measurement and instrumentation (PLC panel) | ||
① Displays input phase voltage, current and accumulated power digitally | ||
② Displays voltage, current, power consumption, and computational power for each module in each phase for each module. | ||
③ Displays voltage, current, and computed wattage for each module and each phase of 3 input phases | ||
4. Safety shut-off device | ||
① Input power emergency shut-off switch | ||
② Operation cut-off switch for each phase | ||
5. Safety device: A safety device in case of continuous operation of one module | ||
① In the case the heat of the power element exceeds the specified value, automatic shutdown | ||
② n the case the magnetron element heat generation exceeds the specified value, automatic shutdown | ||
6. Ground reference | ||
Grounding above 3 types | ||
7. Spare Module | ||
Spare modules: 2 (recommended) | ||
8. Driving preference | ||
① For the purpose of drying wood, it is recommended not to continue operate by exceeding 180 minutes. | ||
② In the case the device is made of sus, when corrosive compounds such as acetic acid are used, the operator must pay attention not to affect corrosion on modules and systems outside the chamber by having a device that collects gas through the vent. (As this product is made of steel, the use of corrosive compounds is prohibited) | ||
③ The operator must check the locking device on the entrance side of the wood outside the device, and severe electromagnetic leakage caused by non-compliance must be the responsibility of the operator. | ||
④ If continuous heating is prolonged, a lot of water condenses inside. So, the operator should clean it using absorbent materials. Neglecting this may cause internal corrosion and shortening of device life. | ||
⑤ If equipment is used in a dusty place, it is recommended that the module is cleaned regularly and the filter is cleaned. |