Advanced wood processing technology using microwave!
1. Product name | ||
PACEP wood sterilizing and drying device (model name: MAMA-5S) | ||
2. Specifications | ||
① Output | 10 2.45GHz Microwave 3kw modules = 30kw total | |
Module specification |
Up to 1.0 kw/hr class Magnetron 3ea 3 electronic power supplies / 3 cooling fans 55w/hr |
|
1 module power consumption | 4.0 kw/hr max | |
② Power consumption | Up to 40KVA or less (including control and fan power) | |
③ Size specification | Maximum size of treated wood | Width 400 Height 650 Length 4,700 (mm) |
Internal standard of processing chamber | Width 8,00 Height 7,00 Length 5,000 (mm) | |
External standard of processing device | Width 1,500 Height 1,000 Length 5,300 (mm) (External connecting rail 5,900 mm) | |
④ Input power | 380V 3-phase, 4-wire (power 3-wire, neutral) | |
grounding | 3 kinds of grounding or more / 50KVA or more | |
⑤ Control panel | Main block switch | 50KVA (recommended) |
Microwave output on/off general control, time control (operation and pause time) | ||
Microwave output on/off for each module | ||
⑥ External air supply fan | 2 units of 25watt class | |
⑦ Material | inner side plate; steel, structure bar & others; steel | |
3. Operation measurement and instrumentation (PLC panel) | ||
① Displays input phase voltage, current and accumulated power digitally | ||
② Displays voltage, current, power consumption, and computational power for each module in each phase for each module. | ||
③ Displays voltage, current, and computed wattage for each module and each phase of 3 input phases | ||
4. Safety shut-off device | ||
① Input power emergency shut-off switch | ||
② Operation cut-off switch for each phase | ||
5. Safety device: A safety device in case of continuous operation of one module | ||
① n the case the heat of the power element exceeds the specified value, automatic shutdown | ||
② In the case the magnetron element heat generation exceeds the specified value, automatic shutdown | ||
6. Ground reference | ||
Grounding above 3 types | ||
7. Spare Module | ||
Spare modules: 2 (recommended) | ||
8. Driving preference | ||
① For the purpose of drying wood, it is recommended not to continue operate by exceeding 180 minutes. | ||
②If continuous heating is prolonged, a lot of water condenses inside. So, the operator should clean it using absorbent materials. | ||
③ The locking device, such as the clasp at the entrance of the wood outside the device, must be well fastened, and there must not be electromagnetic wave leakage caused by non-compliance. |